Power Distribution
Bussmann FRN-R-40 Fuse, 40 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body, Low Voltage,
B087-10178
- For protect of motors and branch circuits
Bussmann FRN-R-50 Fuse, 50 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body, Low Voltage,
B087-10180
- For protect of motors and branch circuits
Bussmann FRN-R-60 Fuse, 60 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body, K
B087-10181
- Bussmann Series fusetron cartridge fuses are 23% more energy efficient and offer the best time-delay performance
- Their dual element feature allows closer sizing to load for great protection of motors and transformers
- Their dual element feature allows closer sizing to load for great protection of motors and transformers
- When sized correctly, they help protect motors from burnout caused by overloads or single-phasing
- The time-delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present
Bussmann NON-100 Fuse, 100 A, 250 VAC, 125 VDC, 10 kA Interrupt, Melamine Body, Cartridge Fuse
B087-10168
- Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- Basic protection 250 V NON Class K5 and H general-purpose, non-current-limiting, one-time fuses
- For agricultural, commercial and industrial applications as well as air conditioning, pumps, appliances, residential fuse panels and other equipment
Bussmann NON-15 Fuse, 15 A, 250 VAC, 125 VDC, 50 kA Interrupt, Melamine Body, Cartridge Fuse
B087-10156
- Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- Basic protection 250 V NON Class K5 and H general-purpose, non-current-limiting, one-time fuses
- For agricultural, commercial and industrial applications as well as air conditioning, pumps, appliances, residential fuse panels and other equipment
Bussmann NON-20 Fuse, 20 A, 250 VAC, 125 VDC, 50 kA Interrupt, Melamine Body, Cartridge Fuse
B087-10157
- Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- Basic protection 250 V NON Class K5 and H general-purpose, non-current-limiting, one-time fuses
- For agricultural, commercial and industrial applications as well as air conditioning, pumps, appliances, residential fuse panels and other equipment
Bussmann NON-30 Fuse, 30 A, 250 VAC, 125 VDC, 50 kA Interrupt, Melamine Body, Cartridge Fuse
B087-10159
- Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- Basic protection 250 V NON Class K5 and H general-purpose, non-current-limiting, one-time fuses
- For agricultural, commercial and industrial applications as well as air conditioning, pumps, appliances, residential fuse panels and other equipment
Bussmann NON-40 Fuse, 40 A, 250 VAC, 125 VDC, 50 kA Interrupt, Melamine Body, Cartridge Fuse
B087-10161
- Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- Basic protection 250 V NON Class K5 and H general-purpose, non-current-limiting, one-time fuses
- For agricultural, commercial and industrial applications as well as air conditioning, pumps, appliances, residential fuse panels and other equipment
Bussmann NON-45 Fuse, 45 A, 250 VAC, 125 VDC, 50 kA Interrupt, Melamine Body, Cartridge Fuse
B087-10162
- Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- Basic protection 250 V NON Class K5 and H general-purpose, non-current-limiting, one-time fuses
- For agricultural, commercial and industrial applications as well as air conditioning, pumps, appliances, residential fuse panels and other equipment
Bussmann NON-60 Fuse, 60 A, 250 VAC, 125 VDC, 50 kA Interrupt, Melamine Body, Cartridge Fuse
B087-10164
- Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- NON one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur
- Basic protection 250 V NON Class K5 and H general-purpose, non-current-limiting, one-time fuses
- For agricultural, commercial and industrial applications as well as air conditioning, pumps, appliances, residential fuse panels and other equipment
Bussmann SC-15 Fuse, 15 A, 600 VAC, 170 VDC, 100 kA Interrupt, Melamine Body, AG, Low Voltage, Time
B087-25015
- For use in mobile home and industrial, residential
Bussmann SC-20 Fuse, 20 A, 600 VAC, 170 VDC, 100 kA Interrupt, Melamine Body, AH, Low Voltage, Time
B087-25020
- For use in mobile home and industrial, residential
Bussmann SC-30 Fuse, 30 A, 480 VAC, 300 VDC, 100 kA Interrupt, Melamine Body, AJ, Low Voltage, Time
B087-25030
- For use in mobile home and industrial, residential
Bussmann SL-15 Plug Fuse, 15 A, 125 V, 10 kA Interrupt, Low Voltage, Time Delay Fuse
B087-10151
- Medium-duty time delay rejection base fuse
- Has ability to withstand typical motor starting surges
- Has ability to withstand typical motor starting surges
- Use in residential or light-duty motor circuits
- These fuses thread into SA adapters
Bussmann SL-20 Plug Fuse, 20 A, 125 V, 10 kA Interrupt, Low Voltage, Time Delay Fuse
B087-10152
- Medium-duty time delay rejection base fuse
- Has ability to withstand typical motor starting surges
- Has ability to withstand typical motor starting surges
- Use in residential or light-duty motor circuits
- These fuses thread into SA adapters
Bussmann SL-25 Plug Fuse, 25 A, 125 V, 10 kA Interrupt, Time Delay Fuse
B087-10153
- Medium-duty time delay rejection base fuse
- Has ability to withstand typical motor starting surges
- Has ability to withstand typical motor starting surges
- Use in residential or light-duty motor circuits
- These fuses thread into SA adapters
Bussmann SL-30 Plug Fuse, 30 A, 125 V, 10 kA Interrupt, Low Voltage, Time Delay Fuse
B087-10154
- Medium-duty time delay rejection base fuse
- Has ability to withstand typical motor starting surges
- Has ability to withstand typical motor starting surges
- Use in residential or light-duty motor circuits
- These fuses thread into SA adapters
Bussmann T-20 Plug Fuse, 20 A, 125 V, 10 kA Interrupt, Plastic Body, Low Voltage, Time Delay Fuse
B087-10122
- Heavy-duty time delay plug fuse
- Use to protect critical motor circuits or motors that cycle On/Off frequently
- Use to protect critical motor circuits or motors that cycle On/Off frequently
- An industrial or commercial-grade product with dual-element construction
- More time delay than the medium-duty type TL fuses in order to better protect industrial motors and critical residential circuits
Bussmann TL-25 Plug Fuse, 25 A, 125 V, 10 kA Interrupt, Plastic Body, Low Voltage, Time Delay Fuse
B087-10133
- Medium-duty time delay plug fuse
- Will withstand typical motor starting surges
- Will withstand typical motor starting surges
- Use in residential or light-duty circuits that contain electric motors
- Edison base size
Bussmann TL-30 Plug Fuse, 30 A, 125 V, 10 kA Interrupt, Plastic Body, Low Voltage, Time Delay Fuse
B087-10134
- Medium-duty time delay plug fuse
- Will withstand typical motor starting surges
- Will withstand typical motor starting surges
- Use in residential or light-duty circuits that contain electric motors
- Edison base size
Carlon 15005-100 Flexible Conduit, 100 ft L, PVC, Gray
C103-23305
- Lightweight for easy handling, transportation and installation
- Crush-, abrasion- and strain-resistant
- Crush-, abrasion- and strain-resistant
- Provides superior wire protection
- Smooth interior ideal for pulling cable, no jagged edges